Hand-held pneumatic grinding machine
Hand-held pneumatic grinding machine
Hand-held pneumatic grinding machine
Hand-held pneumatic grinding machine
Hand-held pneumatic grinding machine

Hand-held pneumatic grinding machine

  • BrandGold chelate
  • ColorSilver
  • OriginShenzhen
Details






Features:

Form: Handheld

Power source: compressed air

Grinding blade: universal

At present, it is the most widely used electrode dressing machine, driven by compressed air. It is widely used because it is easy to obtain power source, safe, light, easy to operate, stable and durable. 




physical dimension:


Precautions and confirmations before operation:

1. Be sure to confirm that the welding switch is off when using.

2. Please confirm that the shape of the tool and electrode cap match;

3. Please correctly install and confirm whether the rotation direction of the KTW blade is clockwise (arrow direction).


Reasons for poor grinding:

(1) The copper scrap after cutting remains on the electrode cap.

(2) The tool does not match the electrode.

(3) The grinding time is too short.

(4) The set grinding position offset (the electrode position deviates greatly from the tool turning center).

(5) The grinding interval is too long and the electrode is deformed greatly.

(6) Electrode eccentricity and electrode tilt are greater than 15°.



Regularly clean the grinding machine to remove the welding slag and copper scrap attached to the body, paying attention to the maintenance and maintenance of the grinding machine. Please do not dismantle it when a malfunction occurs. Please contact us and you may not be able to repair it after disassembly.






    Write a Comment
    Six multiply Three =
    Comment will be posted after it is reviewed.